The Flawless Rhino DC Pump
"Industry-first 24-month free after-sales service warranty"
Rhino DC Pump
The Rhino DC Pump is a high-performance pump with its own dedicated controller, built to meet every user requirement.
An automatic safety feature shuts the pump down when an electrical fault is detected.
Near-silent and powerful, in a compact body. It is built with top-quality materials and components for safety and durability, and offers excellent value compared with competing products.
The secret to quiet yet powerful operation is the turbine design of the internal propeller. Its unique structure keeps the effect on water flow to a minimum, even with long pipe runs that include elbows.
In plumbing systems where the return pump's output is sent through an overflow outlet and spun in a rotary fashion, the flow is usually obstructed and the output drops sharply. With the Rhino pump's new design this does not happen, so the output stays very strong.
The sleek black controller is very easy to use and offers three easy-to-read flow-variation options.
Product Features
Controller with 20-step pump speed control.
High-quality ceramic shaft and high-strength bearings.
Built-in automatic safety shutdown when an electrical fault is detected.
For both saltwater and freshwater aquariums.
6-pole intelligent 3-phase DC drive.
Safe and efficient 24V.
Multifunction module.
Controller
The [–] button reduces flow and lowers energy consumption.
The [+] button increases flow and raises energy consumption.
The FEED button stops the pump for 10, 20 or 30 minutes for feeding or maintenance.
The pump restarts automatically after 10, 20 or 30 minutes, or you can restart it manually.
RHINO INTEGRATED PUMPS specifications
Model: RHINO 1500 | 2500 | 3500
Output: 1500 L/H | 2500 L/H | 3500 L/H
Maximum head: 2 m | 3 m | 3.5 m
Maximum power: 10W | 15W | 20W
Minimum power: 3W | 5W | 5W
Power supply: DC 24V
Size: 124 x 58 x 79mm
Inlet / outlet: 13/20mm | 20/25mm | 20/25mm
Rhino DC Pump Installation
1. Connect the pump with a barb fitting (included) or a threaded fitting (not included) and the tubing of your choice. To minimize leaks, use the included O-ring with the barb fitting, and tighten the hose barb retaining collar by hand only. Do not use tools, as this may cause damage.
2. Place the pump in the water, taking care that the connector at the end of the cord does not get submerged. If the connector gets wet, it must be completely dried before use.
3. Connect the pump power cable to the controller. Make sure the connection is firm and secure, and use the waterproof retaining collar to reduce exposure to moisture.
4. Connect the power supply to the controller.
5. Install the controller and power supply in a place free from heat, water and moisture, ideally somewhere well ventilated so the components stay cool.
6. Re-check all connections.
7. Connect the power cord to the power supply.
8. Plug the power cord into a grounded outlet.
Safety Information
Take particular care when installing and using the pump. This product is an electrical device and requires the same caution as any electrical equipment used with an aquarium. Neglecting this can result in electric shock, fire, serious injury or death. Follow the safety requirements carefully. Failure to do so voids the warranty and may create a serious safety hazard.
Pump Maintenance
Always disconnect the power supply from the mains before installing or servicing the pump.
1. Regular maintenance extends the life of the pump. To clean it, unplug it from the power source, disassemble all parts, remove debris from the inside with a soft brush while rinsing with fresh water, then reassemble. Note: the pump impeller shaft cannot be separated from the impeller.
2. Check the impeller regularly for signs of wear and replace it as needed. Note: the impeller is not covered by the warranty.
3. Always check the condition of the pump O-ring and replace it if it is damaged.
Care and Maintenance
Clean the pump regularly to keep it running efficiently.
If there is water on top of the controller, wipe it off so that moisture cannot get inside.
If the pump suddenly stops, check the adapter first. Then remove the pump's base feet, turn the pump lid counterclockwise to open it, and clean the inside.
Keep the controller and adapter from falling into water, which can cause failure.
Caution
Keep the controller and adapter away from water.
Do not open or disassemble the controller or adapter.
1. Equipment name / model: Rhino DC Pump / RHINO 4000
2. Certification number: R-R-Kyi-RHINO4000
3. Derived models: RHINO1500, 2000, 6000, 12000, 20000, 25000, 30000
4. Company name: Comeyong International
5. Date of manufacture: marked separately
6. Manufacturer / country of origin: QINGDAO MANCE AQUA TECHNOLOGY CO.,LTD / China

- 배송비 : 기본배송료는 4,000원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다) 350,000원 이상 구매시 무료배송입니다.
- 본 상품의 평균 배송일은 2일입니다.(입금 확인 후) 설치 상품의 경우 다소 늦어질수 있습니다.[배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.]
- 본 상품의 배송 가능일은 2일 입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다. (단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)
- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.
- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)
- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.
- 제품의 경우, 제품 및 본 상품의 박스 훼손, 분실 등으로 인한 상품 가치 훼손 시 교환 및 반품이 불가능 하오니, 양해 바랍니다.
- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오.
- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.
- A/S는 판매자에게 문의하시기 바랍니다.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?
RHINO 1500 Amphibious ...
77,000원
골든 트레발리(5-10cm)_107_Gn...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
골든 트레발리(3-5cm)_106_Gna...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
블랙밴드 트레발리(5-10cm+)_105...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
레드 엠페러 스내퍼(15-20cm)_11...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
RHINO Wave Pump TWP60
82,000원
앰버잭(10-15cm)_128_Serio...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
험프백 레드 스내퍼(30-35cm)_11...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
무명갈전갱이(25-30cm)_102_Ca...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다
레드 엠페러 스내퍼(5-10cm)_115...
해당 카테고리는 아쿠아리움 회원만 구매 가능합니다